Conservative management of a cervically fractured zygomatic implant using a novel titanium device: a technical report with biomechanical validation and 24-month follow-up

Duarte, Fernando and Ramos, Carina and Soares, Michel and Martínez-Rodriguez, Natalia and Barona-Dorado, Cristina and Martínez-González, José María UNSPECIFIED (2026) Conservative management of a cervically fractured zygomatic implant using a novel titanium device: a technical report with biomechanical validation and 24-month follow-up. Journal of Stomatology Oral and Maxillofacial Surgery, 127 (5). p. 102983. ISSN 24687855

[img]
Preview
Text
1-s2.0-S2468785526002831-main.pdf

Download (2MB) | Preview

Abstract

Fracture of a zygomatic implant is an uncommon but clinically challenging complication. Conventional management generally involves implant removal or alternative anchorage strategies, both of which may require extensive surgery, increase patient morbidity, and compromise an existing implant-supported rehabilitation. This technical report describes the development, biomechanical validation, and first clinical application of a novel prosthetic rescue device for the conservative management of cervical fractures of zygomatic implants while preserving the osseointegrated apical segment. A customized Grade V titanium device incorporating an internal threaded connection and supplementary self-tapping fixation screws was specifically designed to restore the fractured implant. Biomechanical performance was assessed by dynamic fatigue testing according to ISO 14801. The device was subsequently used in a 60-year-old woman presenting with a cervical fracture of a zygomatic implant. Placement was performed using a surgical guide, and the device was secured with an insertion torque of approximately 20 Ncm. Fatigue testing demonstrated mechanical resistance exceeding five million loading cycles under a maximum load of 129 N. At the 24-month follow-up, the patient remained free of mechanical or biological complications, with stable clinical and radiographic findings and successful maintenance of the implant-supported prosthetic rehabilitation. This case suggests that the proposed prosthetic rescue device may represent a minimally invasive alternative to implant removal in carefully selected cases of cervical fracture of zygomatic implants with a stable osseointegrated apical segment. Further clinical studies are required to confirm the reproducibility, long-term mechanical performance, and clinical predictability of this approach.

Item Type: Article
Subjects: Subjects > Biomedicine
Divisions: Europe University of Atlantic > Research > Articles and books
Depositing User: Sr Bibliotecario
Date Deposited: 23 Sep 2026 14:15
Last Modified: 23 Sep 2026 14:15
URI: https://repositorio.funiber.org/id/eprint/30021

Actions (login required)

View Item View Item